Tootekirjeldus
- Automatic mains voltage regulation system AVR (increasing) - allows you to adjust incorrect input voltage to the level acceptable by receivers without the use of batteries.
- Clear Digital Sinus (CDS) system - enables the generation of a pure sinusoidal voltage at the output of the UPS during battery operation.
- Cool Battery Charging (CBC) system - a fast and efficient charging system that reduces charging time and extends the life of the UPS battery.
- Overload, short-circuit, over-voltage and miswiring protection.
- LAN filter (1 Gbit/s) to protect the network card against surges.
- USB HID communication interface compatible with HID Power Devices, allowing the UPS to cooperate with other devices without installing software (the power supply is visible in the system as a battery).
- Network - ups: ~145V - ~280V +/- 2%
- Ups - mains: ~150V - ~275V +/- 2%
- PowerSoft Professional - free software for monitoring and managing power supplies
- Advanced configuration of events - a possibility of creating rules depending on the PSU operation modes, messages and alarms.
- Delay before power supply output is restarted (used with BIOS restart option for computers)
- Application: Small office and home, Server room
- Working temperatures [°C]: 0 ÷ +40
- Cooling: Natural
- Rated input voltage (rms) [V]: ~ 230
- Input voltage range (rms) [V] and tolerance [%]: ~ 160 ÷ 264 (145 ÷ 280) 2
- Rated frequency of the input voltage [Hz]: 50
- Input frequency range [Hz] and tolerance [Hz]: 45 ÷ 55 1
- Switching thresholds: UPS network [V]: ~ 160 ÷ 264 (145 ÷ 280) 2 %
- Nominal output voltage (rms) [V]: ~ 230
- Output voltage range (rms) [V] and tolerance [%] - mains operation : ~ 184 ÷ 264 (167 ÷ 280) 2
- Output voltage range (rms) [V] and tolerance [%] - back-up operation : ~ 230 5
- Output voltage shape (backup / mains operation): Sinusoidal / Same as input
- Rated frequency of the output voltage [Hz]: 50
- Frequency range (tolerance) - mains operation [Hz]: synchronous with mains
- Frequency range (tolerance) - back-up operation [Hz]: 50 1
- Output voltage filtering : LC, RFI/EMI interference filter, varistor suppressor
- Switching thresholds: UPS mains [V]: ~ 165 / 259 (150 / 275) 2 %
- Switchover time to standby operation [ms]: < 3
- Time to return to mains operation [ms]: 0
- Internal batteries: 12 V / 7 Ah VRLA
- Internal battery backup time (100 % / 80 % / 50 % Pmax) [min]: 3 / 4 / 8
- DC circuit nominal voltage [V]: 48
- Maximum UPS internal battery charging time - after 80 % battery discharge [h]: 7
- Transport position: horizontal
- Maximum output wire length [m]: < 10
- Signaling: Acoustic-optical; LED
- Data line filter - RJ45: LAN 1 Gbit/s
- Monitoring and management software: PowerSoft Professional
- Cold start: yes
The power supply generation of the SINLINE USB HID series provides full power protection for advanced single and multi-processor servers, PCs, computer terminals and small to medium-sized networks.
Characteristics:
Extended switching thresholds (possible to be set using the PowerSoft software) with the following values:
Lisainfo
EAN | 5907683606510 |
---|---|
Manufacturer (A) | Ever |
Manufacturer Code | W/SL00RM-003K00/07 |